CDTHF - REGULAR UNLEADED GASOLINE, CPS201118

  • MSDS: CDTHF
  • Manufacturer: CHEVRON USA PRODUCTS COMPANY
  • Product Name: REGULAR UNLEADED GASOLINE, CPS201118
  • National Stock Number: 9130-00N050856
Product Identification

Product ID:REGULAR UNLEADED GASOLINE, CPS201118
MSDS Date:05/12/1993
FSC:9130
NIIN:00N050856
MSDS Number: CDTHF

Responsible Party
CHEVRON USA PRODUCTS COMPANY
575 MARKET ST
SAN FRANCISCO, CA 94105-2856
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 800-822-5823

Cage: 8X116

Contractor
CHEVRON CHEMICAL CO CONSUMER PRODUCTS DIV
3744 SAN FRANCISCO, CA 94105-2823 US

Telephone: 800-822-5823

Cage: 8X116

Ingredients

INCR LIVER TUMORS-FEMALE MICE; KIDNEY

RTECS: 9999999ZZ


HUMANS-VARIOUS BLOOD DISEASES (APLASTIC ANEMIA TO

RTECS: 9999999ZZ


PHYSICAL DEVEL). CAN CROSS HUMAN PLACENTA. ING

RTECS: 9999999ZZ


ANIMALS-DECR IMMUNOLOGICAL

RTECS: 9999999ZZ


SNIFFERS/HUFFERS)-LIVER, KIDNEY/BRAIN DMG; CHILDREN

RTECS: 9999999ZZ


DEVEL TOX DURING PREGNANCY;

RTECS: 9999999ZZ


LETHALITY (RESORPTIONS) & MALFORMS (PRIMARILY CLEFT

RTECS: 9999999ZZ


MATERNAL TOX (DECR OF SUCCESSFUL

RTECS: 9999999ZZ


FOR MORE SPECIFIC TOXICOLOGICAL INFORMATION CONTACT

RTECS: 9999999ZZ


APPROP HLTH PROFESSIONALS CONCERNING LATEST HAZ LIST

RTECS: 9999999ZZ


GASOLINE (GENERIC) (CONTAINS INGS 2 - 9 & MAY CONTAIN INGS

CAS: 8006-61-9

RTECS: LX3300000

Fraction By Weight: 100%

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM;500 STEL


BENZENE (SARA 313) (CERCLA)

CAS: 71-43-2

RTECS: CY1400000

Fraction By Weight: <4.9%

OSHA PEL 25 PPM, C (MFR)

ACGIH TLV: 10 PPM

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


BENZENE, ETHYL-; (ETHYLBENZENE) (SARA 313)

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: <1.4%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM;125 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


P-XYLENE; (P-DIMETHYLBENZENE) (SARA 313) (CERCLA)

CAS: 106-42-3

RTECS: ZE2625000

Fraction By Weight: <0.9%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM;150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


M-XYLENE; (M-DIMETHYLBENZENE) (SARA 313) (CERCLA)

CAS: 108-38-3

RTECS: ZE2275000

Fraction By Weight: <4.6%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM;150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


O-XYLENE; (O-DIMETHYLBENZENE) (SARA 313) (CERCLA)

CAS: 95-47-6

RTECS: ZE2450000

Fraction By Weight: <2.2%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM;150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: <6.5%

OSHA PEL 200 PPM

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


HEXANE; (N-HEXANE) (CERCLA)

CAS: 110-54-3

RTECS: MN9275000

Fraction By Weight: <30%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


CYCLOHEXANE (SARA 313) (CERCLA)

CAS: 110-82-7

RTECS: GU6300000

Fraction By Weight: <2.4%

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHER, TERT-BUTYL METHYL; (2-METHOXY-2-METHYL PROPANE)

CAS: 1634-04-4

RTECS: KN5250000

Fraction By Weight: <15%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ETHER, TERT-BUTYL ETHYL; (ETHYL TERT BUTYL ETHER (ETBE))

CAS: 637-92-3

RTECS: KN4730200

Fraction By Weight: <18%

OSHA PEL N/K

ACGIH TLV: N/K


ETHYL ALCOHOL; (ETHANOL). (ONLY ADDED IN LIMITED SPECIFIC

CAS: 64-17-5

RTECS: KQ6300000

Fraction By Weight: <10%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


AID TREATMENT CONTACT NEHC .

RTECS: 9999999ZZ


EYE & SPEED & THOROUGHNESS OF FIRST AID

RTECS: 9999999ZZ


TOLUENE APPEARS ON NAVY LIST

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 ML/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:EYE:SLIGHTLY IRRIT, PRLNG VISION
IMPAIRMENT, PAIN, TEARS, SWELL, REDNESS & BLURRED VISION.
SKIN:CRACKED/DRY FROM DEFAT. PRACTICALLY NON-TOX IF ABSORBED.
INGEST:SLIGHTLY TOX. CAN DIRECTLY ENTER LUNGS B Y SWALLOWING/VOMIT
(ASPIR). ONCE IN LUNGS, SUBSTANCE IS VERY DFCLT TO REMOVE & CAN
CAUSE SEV INJURY TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:BENZENE:IARC MONOGRAPHS, SUPP, VOL 7, PG
120, 1987:GRP 1. NTP 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC TO BE
(SUPP DATA)
Effects of Overexposure:HLTH HAZ:LUNGS & DEATH. INHAL:SLIGHTLY TOX. CNS
EFTS (HDCH, DIZZ, LOSS OF APPETITE, WEAK & LOSS OF COORD); LOSS OF
CONSCIOUSNESS, COMA & DEATH; PULM EDEMA & BRONCH. INTENTIONAL EXPOS
MAY RSLT IN CONVL S, DELIRIUM & HALLUCINATIONS. TARGET ORG:NERV
SYS. DEGREE OF INJURY WILL DEPEND ON AMT OF MATL THAT GETS INTO
(ING 14)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL MD IMMED . INHAL:REMOVE TO FRESH AIR. SUPPORT
BRTHG (GIVE O*2/ARTF RESP . EYES:IMMED FLUSH W/POTABLE WATER FOR
MINIMUM OF 15 MINS, SEEK ASSISTANCE FROM MD . SKIN:FLUSH W/ COPIOUS
AMTS OF WATER. CALL MD . NOTE TO MD:INGEST OF THIS PROD/SUBSEQUENT
VOMIT CAN RSLT IN ASPIR OF LIGHT HYDROCARBON LIQ WHICH CAN CAUSE
PNEUM. FOR MORE SPECIFIC INFO REGARDING FIRST (ING 13)

Fire Fighting

Flash Point Method:PMCC
Flash Point:<-49F,<-45C
Lower Limits:1.4%
Upper Limits:7.6%
Extinguishing Media:FIRE FIGHTING FOAM:ALCOHOL RESISTANT TYPE (AR)
AFFF, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . READ ENTIRE DOCUMENT. THIS PRODUCT PRESENTS AN EXTREME
FIRE HAZARD.
Unusual Fire/Explosion Hazard:LIQ VERY QUICKLY EVAPS, EVEN AT LOW TEMPS
& FORMS VAP(FUMES) WHICH CAN CATCH FIRE & BURN W/EXPLO VIOLENCE.
INVISIBLE VAP SPREADS EASILY & CAN BE SET ON (SUPDAT)

Accidental Release

Spill Release Procedures:ELIM ALL SOURCES OF IGNIT IN VICIN OF
SPILL/RELS VAP. CLEAN UP SPILLS IMMED, OBSERVING APPROP PRECS.
WATER POLLUTANT; PVNT RELS FROM CONTAM SOIL/WATER & FROM ENTERING
DRAINAGE/SEWER SYS. CLEAN UP SM S PILLS USING APPROP TECHNIQUES
(SORB MATL/ (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN. DO NOT
GET IN EYES. AVOID PRLNG/FREQUENTLY RPTD SKIN CONT. NEVER SIPHON
GAS BY MOUTH. READ & OBSERVE ALL PRECS ON LBL.
Other Precautions:USE ONLY AS MOTOR FUEL. DO NOT USE FOR CLEANING,
PRESS APPLIANCE FUEL/ANY OTHER SUCH USE. DO NOT USE/STORE NEAR
FLAME, SPKS/HOT SURFS. KEEP CNTNR CLSD. DO NOT TRANSFER LIQ TO
UNLABELED CNTNR. DO NOT W ELD, HEAT/DRILL CNTNR. REPLACE (SUPDAT)

Exposure Controls

Respiratory Protection:NO SPECIAL RESP PROT IS NORMALLY REQD. HOWEVER,
IF OPERATING CNDTNS CREATE AIRBORNE CONCS WHICH EXCEED REC EXPOS
STDS, USE OF NIOSH APPRVD RESP IS REQD. REFER TO OSHA BENZENE STD
TO DETERM WHAT TYPE O F RESP IS REQD BASED ON EXPOS LEVELS.
Ventilation:USE THIS MATERIAL ONLY IN WELL VENTILATED AREAS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
SHOWER . SKIN CONTACT CAN BE MINIMIZED BY WEARING PROTECTIVE
CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:FIRE BY MANY SOURCES (PILOT LIGHTS, WELDING EQUIP & ELEC
MOTORS & SWITCHES). EXPLAN OF CARCIN:CARCIN. OSHA REGULATED:29 CFR
1910.1028. HUMAN:MYELOID LEUKEMIA, HODGKINS DISEASE, LYMPHOMA. OTH
ER PREC:CAP/BUNG. EMPTIED CNTNR STILL CNTNS HAZ/EXPLO VAP/LIQ.
SPILL PROC:PUMPING. FOR MORE INFO, CONTACT NEHC .

Chemical Properties

Boiling Pt:B.P. Text:>77F,>25C
Vapor Pres:5-15 @100F
Vapor Density:3-4
Spec Gravity:0.7-0.8
Solubility in Water:INSOLUBLE
Appearance and Odor:ORANGE TO BRONZE LIQUID.
Percent Volatiles by Volume:>99

Stability

Stability Indicator/Materials to Avoid:YES
MAY REACT W/STRONG OXIDIZING AGENTS, SUCH AS CHLORATES, NITRATES,
PEROXIDES, ETC.
Stability Condition to Avoid:NO DATA AVAILABLE.
Hazardous Decomposition Products:NORMAL COMBUSTION FORMS CARBON DIOXIDE
& WATER VAPOR; INCOMPLETE COMBUSTION CAN PRODUCE CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . PLACE CONTAM MATLS IN DISPOSABLE CNTNRS & DISP OF IN
MANNER CONSISTENT W/APPLIC REGS. CONT LOC ENVIRON/HLTH AUTHS FOR
APPROVED DISP OF THIS MATL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.